MECHANICAL INSTALLATION

MECHANICAL INSTALLATION

NOTE: LCN recommends the use of a BodyMount P/N 761222-79 for most Presence Sensor applications. The BodyMount is a 3” standoff that allows the Presence Sensor to be slightly distanced from the face of the closed door. This helps to prevent ghosting caused by slight door movement while closed, and also prevents ghosting when Door Mounted Safety Sensors are used (as the Door Mounted Safety Sensor extrusions at the top of the door are extremely close to the sensor while the door is closed).

1.The extrusion has pre-drilled mounting holes at each end as shown below in pictures 5 & 6.

5

6

Pre Drilled

Mounting Holes

Approx. 9 ¾” Apart

2.Hold the Presence Sensor up to the pre-determined location, and attach using the 2 self-drilling screws that are included with the package, as shown in picture 7 below. It may be necessary to pre-drill a pilot hole (picture 8) in the header for ease of screw installation. Ensure that Presence Sensor is mounted securely at each end.

7

8

3.If Presence Sensor is mounted directly to door header, and cabling is to pass directly into header, drill a ¼” hole next to the Presence Sensor’s left side end cap to allow wire passage into header as shown below. The wire passage hole should be in a location that aligns with the cut out in the end cap as shown below.

9

ELECTRICAL INSTALLATION AND CABLING

Once the Presence Sensor is securely attached to header, cabling & wiring may be completed.

1.Install the 10-pin connector as shown below in picture 10. If wiring the Presence Sensor to a LCN module, refer to the schematic for the respective module.

10

75.5255.02 XXXXXXXX 7940-8770 LCN

1 PWR

 

2 PWR

 

3 COM

 

4 NO

 

5 NC

 

6

IN -

 

7

IN +

10 PIN

 

 

10 PIN

Position

Connection 7-Pin

Wire Color (10-pin cable)

1

12 to 24 V AC / DC

Red

 

+/- 10%

 

2

24 to 24 V AC / DC

Black

 

+/- 10%

 

3

Common

White

4

Normally Open

Green

5

Normally Closed

 

6

Data -

Brown

7

Data +

Blue

Page 3 of 11

Page 4
Image 4
Ingersoll-Rand 7940-8770 Mechanical Installation, Electrical Installation And Cabling, Position, Connection 7-Pin