Electric Shock Hazard: To prevent electrical shock, disconnect power before servicing unit. Use only a properly grounded and polarized electric outlet.

ADJUSTING THE THERMOSTAT

Factory temperature pre-set is

approx. 200°

200˚F. To reset the thermostat

 

to 200°, turn the indicator two

 

notches to the right of vertical.

 

■ Adjust the thermostat slowly, turning the dial

clockwise to increase

temperature or counter clockwise to decrease temperature, then activate faucet handle for 20 seconds to bring in fresh water to be heated at the new setting. Allow 5-7 minutes for water to reach new temperature.

Scalding Hazard: Do not allow

water to boil. May result in severe burns.

SEASONAL STORAGE/DRAINAGE

Anytime the instant hot water dispenser is not used for extended periods of time, unplug and drain unit. If it is below freezing you will need to unplug the unit and drain it.

Disconnect power from unit.

Push hot water dispenser faucet lever and allow water to flow until it is cool.

Shut the cold water supply off at the valve.

Locate and remove drain screw from bottom center of water tank and drain the water into empty pail.

Empty the tank and then reinstall drain screw into the bottom of tank, turning until snug. Do NOT over tighten.

Remove and discard filter cartridge.

To put back into working order, install new filter cartridge, fill tank with water and reconnect the electrical cord. (Refer to Page 9, Step 6B)

CLEANING THE FAUCET AND TANK

Only use mild cleaners to clean the faucet and plastic components.

Cleaners with acids, abrasives, alkaline or organic solvents will result in deterioration of the plastic components and void the warranty.

FILTER GUIDE AND REPLACEMENT

Replace filter cartridge when there is an obvious decrease in water flow to the faucet or if there is an objectionable taste or odor to the water.

When the inlet and outlet ports have been closed and the filter’s internal pressure has been relieved, water (about 2 oz) will discharge from vent line.

If the new filter cartridge cannot be inserted, insert the old one and turn until it stops, remove it and then retry the new cartridge.

Carbon filters should be replaced within 12 months.

Filter replacement instructions:

Replace with an InSinkErator® filter.

Place pan or dish towel under the filter to catch water drainage during change.

Slowly turn the cartridge counter-clockwise completely until it stops (1/4 turn).

Pull cartridge straight down and discard.

Insert new cartridge into filter head.

Top surface of cartridge will become flush with the bottom of the filter head when fully engaged.

Turn the cartridge clockwise until it stops (1/4 turn).

Align the in/out arrow on the head and bracket assembly to the in/out arrow on the cartridge.

Open faucet to expel trapped air.

Run water for 3 minutes before usage.

PROPERTY DAMAGE

Regularly inspect the unit for any signs of leakage. If there are signs of water damage, immediately remove the unit from service.

To avoid water damage from leakage, replace all cut, loose or split tubing.

A drain pan, plumbed to an appropriate drain or outfitted with a leak detector, should be used in those applications where any leakage could cause property damage.