Turn off water supply before starting.

Turn off water supply before starting.

Installation must comply with all state and local laws and regulations.

INSTALLING FILTRATION SYSTEM

1 A

Mark hole locations for filter head

 

and bracket in a spot that allows for

 

filter replacement.

 

Drill 1/8" starter holes and attach

 

bracket to wall with wood screws,

 

turning until snug.

 

Remove red filter cap, insert filter

Personal Injury: Do not locate filter above an outlet or other

cartridge into filter head and twist

clockwise until “LOCK” arrow on the

electrical device. Install head and bracket so that connections

require no stretching, kinking or pinching of tubing.

filter aligns with arrow on bracket.

B

from water

to other

supply line

plumbing

 

fixture

Property Damage: Tube runs need to form to the cabinet’s contours to allow storage space with no sharp bends. Tubes need clean, perpendicular, burr-free cuts to ensure a true fit.

Determine length of tubing required, then cut to length making sure the cut is perpendicular and burr-free.

Insert a white 3/8" tube into inlet side of filter head until it stops.

Press in again to ensure a secure fit.

Insert the other white 3/8" tube into outlet side of filter head until it stops. Press in again to ensure a secure fit.

C Two water dispenser lines

From filter

One water

dispenser line

Plug

From filter

Insert the copper tube(s) from the

water dispenser into the 3/8" to 1/4"

quick-connect fitting.

Connect the white 3/8" tube

from the right outlet on the filter

head into the quick-connect fitting

until it stops. Press in again to

ensure a secure fit.

To remove tube(s) from quick-connector,

depress the release ring and

gently pull tube away.

D

Discharge

tube

From water

To faucet

supply line

 

It is normal for approximetly 2 oz. of water to

discharge when filter is removed.

To redirect filter replacement water discharge, place the supplied 6" clear tube over vent hole on the left side of filter head.