Integra MZA-4.7 Zones, Expansion Bus, Door Bell, 12VDC 1A Power, Amplifier ON Status - “Amp-On”

Models: MZA-4.7

1 28
Download 28 pages 54.25 Kb
Page 6
Image 6
Features—Continued

Features—Continued

advantageous to have different volume control but the same source, or the same volume with separate standby control. Zone linking is setup either via the front panel user interface or by the IMC program.

32 Zones

There are 32 zones of possible control.

On a MZA-4.7 each zone must be different, however in a multiple amplifier stack same zone amplifiers are pos- sible – they simply mimic every parameter.

Expansion Bus

Data, IR, Amp-On & Audio sources are interconnected via the expansion bus.

The expansion bus feature vastly simplifies the installa- tion cabling of an amplifier stack.

One amplifier is connected to another using a 34-way ribbon cable. Connections are made from the output of the first amplifier to the input of the second etc.

All audio sources must be connected to the first ampli- fier.

Note: Video signals are not passed through the expan- sion bus.

Door Bell

Looped 1.5 second mono sounds can be generated as part of a page preset.

Suitable “wav” files are uploaded to the unit using the IMC program. IMC truncates the “wav” files to a suit- able size.

12VDC 1A Power

Two 12VDC jacks are available for powering external accessories – internally fused at 1A (Self-resetting).

Amplifier ON Status – “Amp-On”

Each zone has front panel ON status indication, and 12VDC OUT on the rear panel connector: (1, 2, 3, 4 & #). The # “AMP ON” output is a logic “And” output, i.e. if any zone is ON then the output will be 12V. This is useful for driving a relay that connects AC power to source equipment. The “AMP ON” output’s are pro- tected against shorts. The “AMP ON” outputs default to tracking the preamplifier ON status, but may optionally be set to track the amplifier ON status using the IMC program.

Power Failure Restoration

After an AC power outage the MZA-4.7 restores its set- tings to the pre-interrupted state.

All internal settings are stored in non-volatile memory, except the clock that runs for at least 48 hours on stored power.

Restore Defaults

The MZA-4.7 may be set to the default settings.

Restoring Defaults clears all memory and resets the zone allocations to zones 1 - 4.

Setup Lockout

Locks access to the System Setup and More menus where installation critical adjustments can be made. Password = 1396

Firmware Upgradable

May be updated with the latest operational firmware, using the USB Uploader program.

Provides a degree of future proofing, and flexibility.

6

Page 6
Image 6
Integra MZA-4.7 Zones, Expansion Bus, Door Bell, 12VDC 1A Power, Amplifier ON Status - “Amp-On”, Power Failure Restoration