Intel A21721-001 manual Fast Ethernet Modules, Possible, Symptom, Cause, Course of Action

Models: A21721-001

1 22
Download 22 pages 39 Kb
Page 22
Image 22
Use the clear fdb

C H A P T E R 3

Fast Ethernet Modules

 

 

 

 

Possible

 

 

 

Symptom

Cause

Course of Action

 

 

 

 

 

 

 

No connectivity

No link. Link on

See “No Link LED”

 

 

with a station on a

10/100 module is

symptom above.

 

 

switch port.

off.

 

 

 

Test for connectivity with

 

 

 

 

 

 

 

 

the ping command.

 

 

 

 

 

 

 

 

Cable has just

Use the clear fdb

 

 

 

been moved from

command or wait until the

 

 

 

one port to

aging time has expired if

 

 

 

another.

the destination is not

 

 

 

 

generating traffic. The set

 

 

 

 

agingtime command

 

 

 

 

establishes the aging time.

 

 

 

 

 

 

 

 

Spanning Tree

Wait 60 seconds for state

 

 

 

has just been

to change to “forwarding.”

 

 

 

enabled.

 

 

 

 

 

 

 

 

Poor performance

A considerable

Use the show counters

 

 

on a link.

amount of Data

command to display them.

 

 

 

Link errors such

Or, use any SNMP-based

 

 

 

as CRC errors.

network management tool

 

 

 

 

to generate reports based

 

 

 

Too many

on these counters.

 

 

 

collisions.

 

 

 

 

 

Too many stations on the

 

 

 

 

segment. Try moving

 

 

 

 

some to their own

 

 

 

 

segment.

 

 

 

 

 

 

 

 

Late Collisions.

Cables are too long. Use a

 

 

 

 

shorter cable, or add a

 

 

 

 

repeater or bridge.

 

 

 

 

 

There are too many “hops.” Use fewer devices from end to end.

19

Page 22
Image 22
Intel A21721-001 Fast Ethernet Modules, Possible, Symptom, Cause, Course of Action, Use the clear fdb, agingtime command