Specification Update 25
BU13. MCi_Status Overflow Bit May Be Incorrectly Set on a Single Instance of a DTLB ErrorProblem: A single Data Translation Look Aside Buffer (DTLB) error can incorrectly set the
Overflow (bit [62]) in the MCi_Status register. A DTLB error is indicated by MCA error
code (bits [15:0]) appearing as binary value, 000x 0000 0001 0100, in the MCi_Status
register.
Implication: Due to this erratum, the Overflow bit in the MCi_Status register may not be an accurate
indication of multiple occurrences of DTLB errors. There is no other impact to normal
processor functionality.
Workaround: None identified.
Status: For the steppings affected, see the Summary Tables of Changes.
BU14. Debug Exception Flags DR6.B0-B3 Flags May be Incorrect for Disabled BreakpointsProblem: When a debug exception is signaled on a load that crosses cache lines with data
forwarded from a store and whose corresponding breakpoint enable flags are disabled
(DR7.G0-G3 and DR7.L0-L3), the DR6.B0-B3 flags may be incorrect.
Implication: The debug exception DR6.B0-B3 flags may be incorrect for the load if the
corresponding breakpoint enable flag in DR7 is disabled.
Workaround: None identified.
Status: For the steppings affected, see the Summary Tables of Changes.
BU15. LER MSRs May Be UnreliableProblem: Due to certain internal processor events, updates to the LER (Last Exception Record)
MSRs, MSR_LER_FROM_LIP (1DDH) and MSR_LER_TO_LIP (1DEH), may happen when
no update was expected.
Implication: The values of the LER MSRs may be unreliable.
Workaround: None Identified.
Status: For the steppings affected, see the Summary Tables of Changes.
BU16. Storage of PEBS Record Delayed Following Execution of MOV SS or STIProblem: When a performance monitoring counter is configured for PEBS (Precise Event Based
Sampling), overflow of the counter results in storage of a PEBS record in the PEBS
buffer. The information in the PEBS record represents the state of the next instruction
to be executed following the counter overflow. Due to this erratum, if the counter
overflow occurs after execution of either MOV SS or STI, storage of the PEBS record is
delayed by one instruction.
Implication: When this erratum occurs, software may observe storage of the PEBS record being
delayed by one instruction following execution of MOV SS or STI. The state information
in the PEBS record will also reflect the one instruction delay.
Workaround: None identified.