Intel EE110EM manual Connecting to a device at full-duplex, Connecting to a switch at full-duplex

Models: EE110EM

1 21
Download 21 pages 52.82 Kb
Page 8
Image 8
Connecting to a device at full-duplex

NOTE

A long press is held for 2 seconds or more.

A short press is held for less than 2 seconds.

Connecting to a device at full-duplex

Express 10/100 Stackable Hubs operate at half-duplex. The only way to connect to a device at full-duplex is with an Ethernet Module.

Connecting to a switch at full-duplex

Not all device manufacturers implement auto-negotiation of duplex mode. To ensure the Ethernet Module connects to the device at full- duplex, force the duplex mode to full-duplex.

To force the duplex mode, use the Change duplex button:

1Long press the Change duplex button. The Auto-negotiate LED blinks.

2Short press the Change duplex button. The Full-duplex LED blinks.

3Long press the Change duplex button. The Full-duplex LED stays on solid.

4Configure the device on the other end for full duplex. (See the device’s documentation for specific instructions.)

To force the speed, follow the steps above using the Change speed button.

Example configurations

Connecting to a switch at full-duplex

 

 

Ethernet Module

or

 

 

 

 

Change

Auto-negotiate

Change

Auto-negotiate

Coll

duplex

 

speed

 

Full-duplex

100 Mbps

 

 

 

 

 

Half-duplex

 

10 Mbps

 

 

 

 

MDI

MDI-X

This is an Ethernet Module plugged into a hub running at 100 Mbps. The module is then connected to a 100 Mbps switch using

CAT 5 TPE cable. The module was forced to run in full-duplex mode.