(Optional) Connecting multiple hubs

Connecting hubs running at 100 Mbps to hubs running at 10 Mbps

Use an Intel Cascade Cable to connect the hubs. Hubs running at 100 Mbps can talk to each other, and hubs running at 10 Mbps can talk to each other. However, hubs running at 100 Mbps can’t talk to hubs running at 10 Mbps without bridging equipment. See pages 5-7 for more information.

Optional bridging

equipment

 

Intel Express

 

 

10/100 Stackable Hub

 

 

 

 

 

 

 

 

 

Intel Express

10/100 Stackable Hub

Intel Express

10/100 Stackable Hub

Intel Express

10/100 Stackable Hub

Category 5 TPE (100m max.)

Category 3, 4, or 5 TPE (100m max.)

Hub 1 (100 Mbps)

Hub 2 (100 Mbps)

Hub 3 (10 Mbps)

Hub 4 (10 Mbps)

Hubs 1 and 2 are in one collision domain and share 100 Mbps of bandwidth.

Hubs 3 and 4 are in a separate collision domain from 1 and 2 and share 10 Mbps of bandwidth.

The optional bridging equipment allows hubs 1 and 2 to talk to hubs 3 and 4.

Connect hubs with an Intel Cascade Cable (product code EE110CC)

Connecting hubs running at 100 Mbps

Use an Intel Cascade Cable to connect the hubs. You can connect a maximum of eight hubs. See page 4 for more information.

Hub 1

Hub 2

Never connect hubs running at 100 Mbps with TPE cable. Doing so violates the IEEE 802.3u Fast Ethernet standard for Class I hubs.

Connect hubs with an Intel Cascade Cable (product code EE110CC)

Connecting hubs running at 10 Mbps

Use an Intel Cascade Cable to stack the hubs or daisy-chain the hubs with TPE cable. All hubs in a stack share 10 Mbps of bandwidth and count as one repeater hop. Hubs connected with TPE cable count as two repeater hops. See page 4 for more information.

Hub 1

Hub 2

or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Intel Express

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Intel Express

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/100 Stackable Hub

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/100 Stackable Hub

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connect hubs with an Intel Cascade Cable

Connect hubs with CAT 3, 4, or 5 TPE cable.

(product code EE110CC)

Limit distance to 100 meters.

2

Page 4
Image 4
Intel PCLA2152B manual Connecting hubs running at 100 Mbps, Connecting hubs running at 10 Mbps