Appendix B: Integrated BMC Sensor Tables108
IntelP®P Server Board S3420GP TPS
Revision 1.0 Intel order number E65697-003
Sensor Name3Sensor
#
Platform
Applicabilit
y
Sensor
Type
Event /
Reading
Type
Event Offset
Triggers
Contrib.
To System
Status
Assert /
De-
assert
Readabl
e
Value /
Offsets
Event
Data
Rearm Stand
-by
Fan Tach Sensors 30h–
34h
Chassis-
specific
Fan
04h
Threshold
01h [l] [c,nc]
nc =
Degraded
c = Non-
fatal2
As and
De Analog R, T M
Processor Therm
Margin 62h All
Temperatur
e
01h
Threshold
01h – – Analog
Processor Therm Ctrl % 64h All
Temperatur
e
01h
Threshold
01h [u] [c] Non-fatal As and
De Analog Trig Offset A
Processor VRD Temp 66h All
Temperatur
e
01h
Digital
Discrete
05h
01 - Limit
exceeded Fatal As and
De – Trig Offset M
CATERR 68h All
Processor
07h
Digital
Discrete
03h
01 – State
Asserted Non-fatal As and
De – Trig Offset M
PCH Thermal Trip 6Ah All
Temperatur
e
01h
Digital
Discrete
03h
01 – State
Asserted Fatal As and
De – Trig Offset M