Troubleshooting

40 Intel Server Board SE7210TP1-E User Guide

LED Information

The Intel® Server Board SE7210TP1-E includes LEDs that can aid in troubleshooting your system.

A table of these LEDs with a description of their use is listed below.

LED Name Function Location Color Correction
ID Aid in server
identification from the
back panel
Front Panel and
board rear left
corner
Blue Press ID LED button or user
Server Management
software to turn off the LED.
System fault Visible fault warning Front panel and
board rear left
corner
Green or Amber On = No Fault
Green Blink = degraded
Amber = critical error or
non-recoverable
Amber blink = non-critical
IDE activity Front panel Front panel and
board left side Green Blinking = Activity. No action
required.
Memory fault
1–6 Identify faili ng memory
module DIMM end front of
board Amber On = Fault
POST code 1–4
(LSB, bit1, bit2,
MSB)
Display boot 80 POST
code Left rear of board Each LED can be
Off, Green,
Amber, Red
See the POST code table
Fan Pack Fault Warn on fan failure Front center board Amber On = Fault
CPU 1 & 2 Fan
Fault Identify fan failure Front center board Amber On = Fault
CPU 1 & 2
Fault Identify processor failure 1” behind processor
socket Amber On = Fault
5v Standby Identify 5v standby
power on state Front left board Amber On = 5v standby power o n
Power LED Identify the po wer state
of the system Front Panel Green Off = Power is off (off or
S5)
On = Power on or S0)
Slow Blink = Low power
state (S1 – S3)