Intel SIU520 SS7 manual SS7 Network, Hardware Requirements, Configuring a Dual SIU Pair

Models: SIU520 SS7

1 28
Download 28 pages 60.74 Kb
Page 20
Image 20
SS7 Network

Building Fault-tolerant SS7 Systems Using the Intel® NetStructure™ SIU520 SS7 Signaling Gateway Application Note

Signaling Card

PCM Trunk #0

PCM Trunk #1

SIUA

PCM Trunk #2

PCM Trunk #3

Signaling Card

PCM Trunk #0

PCM Trunk #1

SIUB

PCM Trunk #2

PCM Trunk #3

SS7 Network

E-1 Trunk Containing

SS7 Signaling Only

Inter-SIU SS7 Link Set E-1 Trunk

SS7 Network

E-1 Trunk Containing

SS7 Signaling Only

Figure 17. Inter-SIU Link over Crossed E-1/T-1 Cable

Configuring a Dual SIU Pair

To create a dual-resilient configuration for the Intel NetStructure SIU520 SS7 signaling gateway, modifications are required to both the system configuration (done using the man machine interface [MMI]) and the protocol configuration (in the config.txt parameter file). This may be done remotely and trans- ferred to the SIU using FTP. More details may be found in the Intel NetStructure SIU520 Developer’s Manual.

Hardware Requirements

Configuring an SIU as one-half of a resilient pair requires additional hardware ports to carry the inter-SIU link set between SIUA and SIUB. This may be achieved using E-1/T-1 interfaces, as shown in Figure 17, or V.11 (V.35) interfaces, as shown in Figure 18. A cable, part number 842484, can be purchased from your Intel distributor to interconnect two V.11 ports between signaling cards within the SIU. For more information, refer to the Intel NetStructure SIU520 Developer’s Manual.

17

Page 20
Image 20
Intel SIU520 SS7 manual SS7 Network, Hardware Requirements, Configuring a Dual SIU Pair