CONSOLE DIAGRAM

CONSOLE DIAGRAM

Temperature

Display

USING THE CONSOLE

Refer to the console diagram above. The function of each console control is explained below:

Temperature Display: During normal use, this dis- play shows the actual water temperature. When the

Set Temp indicator is lit, the display will show the set temperature.

Note: When problems occur, the temperature display may show an error code. The error codes are explained below:

HL High temperature protection mode. If the water temperature rises above 115°F (46°C), the heater will shut off. If the temperature rises

above 122°F (50°C), the high temperature cir- cuit will shut off the entire system. In either

case, once the water has cooled to normal, you can press any button to reset the system.

FrE Freeze protection mode. If the water tempera- ture falls below 40°F (14°C), the pump will begin cycling the water through the heater to raise the temperature. This cycle will run for one minute and may be repeated as needed.

FLC Flow related problems. You will need to call our customer service department.

FLO Flow related problems. You will need to call our customer service department.

PrH High temperature probe problem. You will need to call our customer service department.

Prr Temperature probe problem. You will need to call our customer service department.

Pump Button: This button turns the pump on and off. When the pump is running, the LED indicator above

the button will light. To turn the pump on high, press the button once. The thera-jets will operate at full speed. To turn the pump on low, press the button again. The thera-jets will operate at low speed. After you press the button a third time, the thera-jets will

shut off, unless it is time for the heat or filter cycles. If you turn the pump off and it continues to operate,

check to see if the Heat On or Filter On indicator is lit to see if either cycle is running.

Light Button: This button turns the light on and off. When the light is on, the indicator above the light but- ton will light. Note: The light will automatically turn off after two hours.

Set Temp Indicator: This indicator will light when the temperature is adjusted using the up and down buttons.

The thermostat can be set to heat the water from

70°F to 104°F (21°C to 40°C). While you are setting the temperature, the temperature display will show the temperature setting. The temperature setting will

remain in the display for five seconds after you release the buttons. The Set Temp light will then turn off and the display will show the actual water temper- ature. The water heats at 1.5°F (2°C) per hour with the cover on.

Filter On Indicator: This indicator lights when the spa is running the filter cycle.

Note: To keep the heat and filter cycles from run- ning, shut off the circuit breaker or the GFCI.

Heat On Indicator: This indicator lights when the spa is running the heating cycle.

Air Control: The air control determines the amount of air flowing through the spa jet system during operation. If the control is turned to the left, the amount of air will increase; if the control is turned to the right, the amount of air will decrease.