OPERATING INSTRUCTIONS
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007
110
OPERATING INSTRUCTIONS
1.Make sure the filter pump switch is "OFF". The switch is located on the motor housing.
2.Connect the power cord to a GFCI protected electrical outlet.
WARNING
Risk of electric shock. Connect this product only to a grounding type receptacle protected by a
IMPORTANT
To prevent air lock, open the lower plunger valve (connected inlet hose) first and then the upper plunger valve (connected outlet hose). Open air release valves, wait until water starts to flow out of the air release valves, close air release valves.
3. Grasp a plunger valve handle. Turn the handle
4. With water flowing into filter pump, the water pressure will allow the air trapped inside to escape from the air release valves (2 & 7). When all the air has escaped water will flow out of the valves (2 & 7). When this occurs gently finger tighten the valves (2 & 7) in a clockwise direction.
5. Turn the switch "ON". The filter pump is now filtering the water.
6. Operate the filter pump until the desired water clarity is obtained.
FILTER CARTRIDGE CLEANING OR REPLACEMENT
It is recommended that the filter cartridge be replaced at least every 2 weeks.
1. Make sure the filter pump is turned off, and disconnect the power cord from the electrical outlet.
2. Grasp a plunger valve handle. Turn the handle
3. Gently turn the top air release valve
4. In a
5. Remove the housing cover (4).
SAVE THESE INSTRUCTIONS