Invacare Nutron Series manual Connecting Battery Cables Battery Clamp Method

Models: Nutron Series

1 72
Download 72 pages 63.91 Kb
Page 56
Image 56

SECTION 12—BATTERIES

Battery Clamp Method

WARNING

The battery clamp of the POSITIVE (+) battery terminal/post MUST be mounted in the position shown in FIGURE 12.7, otherwise the battery box top cannot be installed properly.

NOTE: For this procedure, refer to FIGURE 12.7, FIGURE 12.8 and FIGURE 12.9.

Correct Orientation of the POSITIVE (+) Terminal/Post Clamp

POSITIVE (+) Terminal/Post

NEGATIVE (-)

(Note position of clamp)

Terminal/Post Clamp

 

Hex Nut

 

Group 22NF Battery

FIGURE 12.7 Connecting Battery Cables - Battery Clamp Method

1.Perform one (1) of the following:

If the battery clamp of the POSITIVE (+) battery terminal/post is NOT mounted in the orientation shown in FIGURE 12.7, perform the following:

i.Loosen the hex nut that secures the battery clamp to the POSITIVE (+) battery terminal/post.

CAUTION

When tightening the clamps, always use a box wrench. Pliers will “round off” the nuts. NEVER wiggle the battery terminal(s)/post(s) when tightening. The battery may become damaged.

ii.Remove the battery clamp from the POSITIVE (+) battery terminal/post.

iii.Reposition the battery clamp on the POSITIVE (+) battery terminal/post as shown in FIGURE 12.7.

iv.Securely tighten the hex nut that secures the battery clamp to the positive (+) battery terminal/post.

If the battery clamp on the POSITIVE (+) battery terminal/post is positioned as shown in FIGURE 12.7, proceed to STEP 2.

Nutron® Series

56

Part No.1106644

Page 56
Image 56
Invacare Nutron Series manual Connecting Battery Cables Battery Clamp Method