AM-4109/1104 IP510, EP510, IP511, EP511 SERIES

510 and 511 Series I/P AND E/P TRANSDUCER SPECIFICATIONS

Accuracy:

± 0.10% of output span, typical

± 0.25% of output span, maximum

 

Hysteresis:

0.01% of output span, typical

0.10% of output span, maximum

 

Dead Band:

Not measurable

 

 

Repeatability:

0.01% of output span, typical

0.10% of output span, maximum

 

Ambient Temperature Effect

± 0.004% of nominal span per ˚F, typical

± 0.022% of nominal span per ˚F, maximum

Zero:

 

Span:

± 0.013% of calibrated span per ˚F, typical

± 0.022% of calibrated span per ˚F, maximum

 

Compensated Temperature Range:

+32˚F to +122˚F

 

 

Operating Temperature Range

-20˚F to 160˚F

Buna-N elastomers:

0˚F to 160˚F

Viton elastomers:

 

 

 

Storage Temperature Range

-40˚F to 200˚F

Buna-N elastomers:

-15˚F to 200˚F

Viton elastomers:

 

 

 

Vibration Effect:

Less than 0.5% of SPAN per 1G,

5-2000 Hz, 3G maximum, 3 axes

 

Mounting Position Effect:

Not measurable

 

 

Loop Load, I/P transducer:

Less than 10 VDC drop at 20 mA

Less than 12 VDC drop at 50 mA

 

Supply Voltage, E/P Transducer

9 VDC to 28 VDC, less than 20 mA

Intrinsically Safe/Nonincendive:

9 VDC to 40 VDC, less than 20 mA

General Purpose:

 

 

 

Supply Voltage Effect:

Not measurable

 

 

Signal Impedance, E/P Transducer:

6000 Ohm minimum

 

 

RFI/EMI Effect (NEMA 4X):

Less than 0.25% of SPAN, 10V/meter, 20-1000 MHz.

 

 

Supply Pressure Requirements:

See TABLE 1

 

 

Supply Pressure Effect:

Not measurable

 

 

Air Consumption:

6.0 SCFH maximum

 

 

Forward Flow Capacity (Supply):

Standard Range 7 SCFM

Extended Range (over 30 PSI) 12 SCFM

 

Port Sizes:

Pneumatic: 1/4" NPT

Electrical: 1/2" NPT

 

 

 

10

Page 10
Image 10
Iomega EP510 manual Series I/P and E/P Transducer Specifications