AM-4109/1104 IP510, EP510, IP511, EP511 SERIES

MOUNTING

GENERAL

NEMA 1 and NEMA 4X transducers can be mounted in any position.

DIRECT MOUNTING

PIPE

Any NEMA 1 transducers may be supported by its own plumbing for air supply and output. NEMA 4X transducers may also be supported using 1/2" explosion proof conduit in the electrical port.

PANEL

NEMA 1 transducers may be mounted to a panel with two No. 10-32 screws using threaded holes in the back of a trans- ducer or with two to four No. 8-32 screws using threaded holes in the bottom of a transducer.

NEMA 4X transducers may be mounted to a panel with three No. 10-32 screws using threaded holes in the back of a transducer or with four No. 8-32 screws using threaded holes in the bottom of a transducer. In the case of back-mount- ing, if the panel extends towards the screw-on cover, a 3/16-inch-thick spacer MUST be used between the back of the transducer and the panel in order for the panel to clear the transducer's screw-on cover.

EP510 AND IP510

 

FRONT VIEW

SIDE VIEW

BOTTOM VIEW

 

TOP VIEW

 

Drawings and dimensions are for reference only.

4

Page 4
Image 4
Iomega EP510 manual Mounting General, Direct Mounting