6.Post installation

Once you have completed the installation you must:

Ensure the system is running correctly, the LED light on top of the unit is on steady and alarms are being signaled to the Monitoring Centre correctly.

After a short period of inactivity the display will switch off. To switch it back on, touch the display anywhere.

If a fault should develop, then the LED light on the top of the unit will start flashing and the display will show a system fault message. This message can be touched to gain access to more information. Ensure the user is aware of this and what action they need to take should a fault occur.

7.PIN alarms

The IRIS Touch series have PIN inputs [18] that can be used to generate alarm messages. These can be:

Text messages via SMS (GSM / Ethernet & GPRS only).

SIA alarm messages over IP to the Monitoring Centre (Ethernet / Ethernet & GPRS only).

Fast Format alarm messages over IP to the Monitoring Centre (Ethernet / Ethernet & GPRS only).

The messages for each PIN can be configured via the Settings Menu on the touch screen display. See Appendix A for more details.

8 Iris Touch 200 Range Dialer Installation Manual

Page 13
Image 13
IRIS 200 installation manual Post installation, PIN alarms