7.2.Default alarm messages

The default SIA messages for each PIN are shown below:

Pin

‘Set’ message

‘Restore’ message

Meaning

 

 

 

 

1

NBA01

NBR01

Burglary alarm/restore

 

 

 

 

2

NFA02

NFR02

Fire alarm/restore

 

 

 

 

3

NQA03

NQR03

Emergency alarm/restore

 

 

 

 

4

NOP04

NCL04

Open/close

 

 

 

 

8.Relay outputs

The IRIS dialer has two relay outputs [20] that can be used in a number of ways:

To indicate communications path failure.

Activation by incoming SMS Message.

Setting by the Monitoring Centre.

The relay contacts are normally open and closed when activated.

Wire to these contacts as required and define how they are to be used using the configuration options on the Settings Menu. See Appendix A for more details.

9.Troubleshooting

Problem

Resolution

No screen display when IRIS

Check that there is power to the system

dialer is connected to the

and that the wiring is the correct polarity.

power.

 

A fault develops and is

Touch the display and the instructions will

indicated by the LED on the top

guide you through identification of the

of the unit flashing.

problem.

 

Go to the Installers menu and select Test to

 

use the integrated test function.

10 Iris Touch 200 Range Dialer Installation Manual

Page 15
Image 15
IRIS 200 installation manual Relay outputs, Troubleshooting, Default alarm messages