QuietPower 1800 Inverter Owner’s Manual Rev 15 OCT 01 Page 6
2.1.2 Control Panel
The Control Panel provides ‘0/|’(Off/On) control and displays oper ating information so you can monitor
the status of the Inverter and your batteries.
This panel can be removed and re-attached in different orientations so the display inform ation is directed
at you in the most convenient fashion, for all recommended mounting c onfigurations.
3 Installation
This section contains instructions for installing the QuietPower In verter. After securing the unit and
making wiring connections, do not turn the unit on.
Proceed to the next section of the manual which provides operating instr uctions.
3.1 Requirements for Installation
What You Need to Install the QuietPower Inverter
You need the following tools and hardware to properly install the QuietP ower Inverter:
· Wrench for DC terminals (½” or 13 mm)
· Wrench for Vibration Isolators (optional use)
· DC cables (supplied as PN 287A106)
3.2 Locating the QuietPower Inverter
The QuietPower Inverter utilizes complex electronic circuits and although design precautions have been
made for protection of these circuits, they can be susceptible to dam age from use in extreme
environments. The QuietPower Inverter should only be installed in a location that meets the following
requirements:
· Dry: do not allow water or other fluids to drip or splash on the QuietPower Inverter. Do not mount the
QuietPower Inverter in an area subject to splashing or dripping water or bilge.
· Cool: normal ambient air temperature should be between 0°C (32°F) and 25°C (77°F) - the cooler the
better within this range. Refer to the operating temperature information in the specificatio ns section
of this manual.
· Ventilated: allow at least 5 inches (13 cm) of clearance all around the unit. Ensure that the ventilation
openings on the unit are not obstructed. If mounting in a compartment, ventilate with louvers or cut-
outs.
· Safe: do not install the QuietPower In verter in the same compartment as batteries or in any
compartment capable of storing flammable liquids such as gasoline. Do not install the QuietPower
Inverter in an engine compartment or other location where ignition prot ected equipment is required.
· Dust-free: do not install the QuietPower Inverter in a dusty environment where either dust, wood
particles or other filings/shavings are present. These can be pulled into the unit when the cooling fan
is operating.
· Close to AC junction box: avoid the use of extended wire lengths if poss ible.
· Close to battery/batteries: Avoid excessive cable lengths but do not install the QuietPower Inverter in
the same compartment as batteries. Use the recommended wire lengths and sizes (see section
3.4.4). Also do not mount the QuietPower Inverter where it will be exposed to the gases produced by
the battery. These gases are very corrosive and prolonged exposure wil l damage the QuietPower
Inverter.
· Protected from battery acid: Never allow battery acid to drip on the QuietPower Inverter or its wiring
when reading specific gravity or filling the battery.