!NOTE

It is very important for installer to verify that intermediate pivot point lines up with center line of top and bottom pivot points before final installation. Both door and frame pivot leafs located from face of door. Intermediate pivot should be evenly spaced between top and bottom pivots. Heel edge of door must be beveled 1/8” in 2”.

Frame Leaf

9/16” 14 mm

Face of door

C

L

3/4”

19 mm

 

 

Door Leaf

 

Reference line

1-1/16”

 

 

27 mm

 

3/8”

C

7/16”

L

10 mm

 

11 mm

 

 

 

3/4”

 

 

19 mm

5/16”

Face

8 mm

 

of door

5/16” 8 mm

Right hand installation shown;

left hand opposite

27070-00

27070 Rev. 3

Page 2