Jackson Avenger LT Problem Rinse water not at required temperature range, Troubleshooting Section

Models: Avenger HT Avenger LT

1 61
Download 61 pages 44.6 Kb
Page 24
Image 24
Problem: Rinse water not at required temperature range.

SECTION 4: TROUBLESHOOTING SECTION

COMMON PROBLEMS

WARNING: Inspection, testing and repair of electrical equipment should be performed only by qualified service per- sonnel. Certain procedures in this section require electrical tests or measurements while power is applied to the machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect power, attach test equipment and reapply power to test. When replacing electrical parts, disconnect power at source circuit breaker.

Problem: Rinse water not at required temperature range.

1.Check that orange/white wires are connected. See note in installation instructions.

2.Thermometer is defective. Replace.

3.Thermostat is defective. Adjust the thermostat. Replace if necessary.

4.Incoming rinse water does not meet minimum criteria indicated on machine data plate. Adjust as required.

Problem: Machine doesn’t drain when “OFF/DRAIN” switch is pressed.

1.Drain solenoid clogged. Remove obstruction.

2.Defective motor or motor start relay. Replace.

3.Defective drain valve. Replace.

Problem: No indication of pressure.

1.Water turned off. Turn water on.

2.Pressure gauge defective. Replace pressure gauge.

Avenger™ Series Technical Manual 7610-003-34-01 Rev. A

Issued: 05-02-2007 Revised: N/A

18

Page 24
Image 24
Jackson Avenger LT, Avenger HT Problem Rinse water not at required temperature range, Problem No indication of pressure