SECTION 1: SPECIFICATION INFORMATION

OPERATING CAPACITIES

PERFORMANCE/CAPABILITIES

 

WATER REQUIREMENTS

 

 

TEMPSTAR:

 

OPERATING CAPACITY:

 

 

 

 

 

(HIGH TEMPERATURE)

 

WASH TEMPERATURE (MINIMUM)(°F)

150

RACKS PER HOUR

58

WASH TEMPERATURE (MINIMUM)(°C)

66

DISHES PER HOUR

1450

RINSE TEMPERATURE (MINIMUM)(°F)

180

GLASSES PER HOUR

1450

RINSE TEMPERATURE (MINIMUM)(°C)

83

 

 

INLET WATER TEMPERATURE:

 

(LOW TEMPERATURE)

 

12KW RINSE HEATER (°F)

140

RACKS PER HOUR

50

12KW RINSE HEATER (°C)

60

DISHES PER HOUR

1250

14KW RINSE HEATER (°F)

110

GLASSES PER HOUR

1250

14KW RINSE HEATER (°C)

44

 

 

FLOW PRESSURE (PSI)

10

 

 

WATER LINE SIZE (NPT)

1/2”

OPERATING CYCLE (SECONDS):

 

DRAIN LINE SIZE (NPT)

1 1/2”

MINIMUM (OTHER CYCLE TIMES ARE AVAILABLE)

 

 

(HIGH TEMPERATURE)

 

TEMPSTAR LT:

 

WASH TIME

40

 

 

RINSE TIME

13

WASH TEMPERATURE (MINIMUM)(°F)

130

DWELL TIME

4

WASH TEMPERATURE (MINIMUM)(°C)

55

TOTAL CYCLE TIME

57

RINSE TEMPERATURE (MINIMUM)(°F)

130

 

 

RINSE TEMPERATURE (MINIMUM)(°C)

55

(LOW TEMPERATURE)

 

INLET WATER TEMPERATURE (°F)

130

WASH TIME

45

INLET WATER TEMPERATURE (°C)

55

RINSE TIME

11

FLOW PRESSURE (PSI)

10

DWELL TIME

10

WATER LINE SIZE (NPT)

1/2”

TOTAL CYCLE TIME

66

DRAIN LINE SIZE (NPT)

1 1/2”

 

 

MINIMUM CHLORINE REQUIRED (PPM)

50

TANK CAPACITY:

 

TEMPSTAR NB/TEMPSTAR S:

 

WASH TANK (GAL)

8.0

 

 

 

WASH TANK (L)

30.3

WASH TEMPERATURE (MINIMUM)(°F)

150

RINSE TANK (TEMPSTAR) (GAL)

3.0

WASH TEMPERATURE (MINIMUM)(°C)

66

RINSE TANK (TEMPSTAR) (L)

11.4

RINSE TEMPERATURE (MINIMUM)(°F)

180

 

 

RINSE TEMPERATURE (MINIMUM)(°C)

83

 

 

INLET WATER TEMPERATURE (°F)

180

STEAM REQUIREMENTS:

 

INLET WATER TEMPERATURE (°C)

83

 

 

FLOW PRESSURE (PSI)

10

COIL SIZE

3/4”

WATER LINE SIZE (NPT)

1/2”

STEAM FLOW PRESSURE (P.S.I.)

10-20

DRAIN LINE SIZE (NPT)

1 1/2”

CONSUMPTION @ 15 P.S.I. (LBS/HR)

45

 

 

ELECTRICAL REQUIREMENTS

 

 

 

WASH MOTOR HP

3/4

 

 

NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice.

Tempstar LT/NB/S Technical Manual 7610-003-61-42 B

Issued: 10-08-2008 Revised: 04/22/2009

2

Page 10
Image 10
Jackson Tempstar S technical manual Specification Information

Tempstar S specifications

The Jackson Tempstar S is a notable name in the realm of industrial heating systems, designed to provide efficient and reliable performance for various applications. Known for its advanced technology and user-friendly features, the Tempstar S stands as a true testament to innovation in heating solutions.

At the core of the Jackson Tempstar S is its powerful heating capacity. This unit can efficiently deliver substantial heat output, making it suitable for large-scale operations. It employs a high-performance burner system that ensures optimal combustion efficiency, translating into reduced fuel consumption and lower operating costs. This energy efficiency is enhanced by advanced control systems that allow for precise temperature regulation.

One of the standout technologies integrated into the Jackson Tempstar S is its advanced control interface. Featuring an intuitive digital display, users can easily monitor and adjust settings. This allows for real-time data feedback, increasing overall usability and operational efficiency. Moreover, the system is designed to offer multiple programmable settings, accommodating a range of operational requirements. This versatility is complemented by robust safety features, including overheat protection and flame monitoring, ensuring that the unit operates safely under various conditions.

Another noteworthy characteristic of the Jackson Tempstar S is its construction. Built with durable materials, the unit is designed to withstand harsh industrial environments. Its compact design allows for easy installation and efficient space utilization, making it a practical choice for facilities with limited space. Additionally, the unit is relatively lightweight, facilitating mobility and ease of repositioning when necessary.

Maintenance is simplified with the Jackson Tempstar S. The design focuses on reducing downtime through easy access to key components, making routine checks and service tasks straightforward. This feature is crucial for industries that rely on continuous operation and cannot afford prolonged interruptions.

Additionally, the Jackson Tempstar S prioritizes eco-friendliness. It adheres to strict emissions standards, contributing to a greener operational footprint without sacrificing performance. This commitment to sustainability reflects the growing emphasis on environmentally conscious manufacturing processes in the industrial sector.

In conclusion, the Jackson Tempstar S offers an impressive combination of efficiency, safety, and ease of use. With its robust features, cutting-edge technology, and durability, it stands as a premier choice for industrial heating applications.