Jackson Tempstar S To Dishmachine Drain, Tee, 1-1/2 x 1-1/2 x 1-1/2 Reducer, 1-1/2 to 1/2

Models: Tempstar S

1 71
Download 71 pages 25.97 Kb
Page 53
Image 53

SECTION 5: PARTS SECTION

Elbow, 1-1/2” 90Street 04730-206-32-00

Nipple, 1-1/2” NPT 04730-207-40-00

Modified Compression

Fitting

05700-001-16-52

Reducer, 1-1/2” x 1/4” 04730-002-55-76

To Dishmachine Drain

Tee, 1-1/2” x 1-1/2” x 1-1/2” 04730-011-69-93

Reducer, 1-1/2” to 1/2” 04730-002-55-75

DRAIN QUENCH ASSEMBLY

Drain Quench

Assembly

06401-002-59-52

Lid, Drain Quench

05700-002-67-16

Thermostat 05930-003-13-65

Solenoid Valve 04810-100-09-18

To Cold Water Supply

Box, Drain Quench 05700-002-69-96

Valve, Check, 1/2”

 

(Not Shown)

Nipple, Close, 1/2” NPT

04820-002-55-77

(Not Shown)

 

04730-207-15-00

From the existing drain, attach the two additional Tees using the 1-1/2” NPT Close Nipples. Tighten the Reducers into the Tees as shown above. Attach the Modified Compression Fitting into the 1-1/2” to 1/4” Reducer. Position the bulb of the thermostat so that it rests approximately 1/4” from the bottom of the Tee. Tighten the Modified Compression Fitting as required. Attach to the incoming cold water line. Use pipe dope or thread tape as required to prevent any leaks.

Tempstar LT/NB/S Technical Manual 7610-003-61-42 B

Issued: 10-08-2008 Revised: N/A

45

Page 53
Image 53
Jackson Tempstar S To Dishmachine Drain, Tee, 1-1/2 x 1-1/2 x 1-1/2 Reducer, 1-1/2 to 1/2, Drain Quench Assembly