Jackson Tempstar S technical manual Volts Ratings Amps Circuit, Rinse Typical

Models: Tempstar S

1 71
Download 71 pages 25.97 Kb
Page 11
Image 11

SECTION 1: SPECIFICATION INFORMATION

ELECTRICAL REQUIREMENTS

NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service contractor that your circuit protection is ade- quate and meets all applicable national and local codes. These numbers are provided in this manual simply for ref- erence and may change without notice at any given time.

TEMPSTAR:

 

 

 

 

TEMPSTAR LT/TEMPSTAR NB:

 

 

 

 

 

RINSE

 

TYPICAL

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL ELECTRICAL

 

 

 

HEATER

TOTAL ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

1

50

12KW@240V

71 A

90 AMP

208

1

50

N/A

28 A

35 AMP

208

1

50

14KW@240V

78 A

100 AMP

230

1

50

N/A

30 A

40 AMP

230

1

50

12KW@240V

78 A

100 AMP

 

 

 

 

 

 

230

1

50

14KW@240V

86 A

110 AMP

208

3

50

N/A

20 A

25 AMP

 

 

 

 

 

 

230

3

50

N/A

21 A

30 AMP

208

3

50

12KW@240V

45 A

60 AMP

380

3

50

N/A

10 A

15 AMP

208

3

50

14KW@240V

49 A

70 AMP

415

3

50

N/A

10 A

15 AMP

230

3

50

12KW@240V

48 A

60 AMP

440

3

50

N/A

8 A

15 AMP

230

3

50

14KW@240V

53 A

70 AMP

 

 

 

 

 

 

380

3

50

12KW@380V

29 A

40 AMP

208

1

60

N/A

26 A

35 AMP

380*

3

50

14KW@208V

34 A

45 AMP

230

1

60

N/A

28 A

35 AMP

415

3

50

12KW@415V

26 A

35 AMP

 

 

 

 

 

 

415

3

50

14KW@415V

29 A

40 AMP

208

3

60

N/A

18 A

25 AMP

440

3

50

12KW@460V

21 A

30 AMP

230

3

60

N/A

28 A

35 AMP

440

3

50

14KW@460V

25 A

35 AMP

460

3

60

N/A

8 A

15 AMP

208

1

60

12KW@240V

69 A

90 AMP

 

 

 

 

 

 

208

1

60

14KW@240V

76 A

100 AMP

TEMPSTAR S:

 

 

 

 

230

1

60

12KW@240V

76 A

100AMP

 

 

 

RINSE

 

TYPICAL

230

1

60

14KW@240V

84 A

110 AMP

 

 

 

HEATER

TOTAL ELECTRICAL

 

 

 

 

 

 

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

3

60

12KW@240V

43 A

60 AMP

208

1

60

N/A

6 A

15 AMP

208

3

60

14KW@240V

47 A

60 AMP

230

1

60

N/A

6 A

15 AMP

230

3

60

12KW@240V

46 A

60 AMP

 

 

 

 

 

 

230

3

60

14KW@240V

51 A

70 AMP

208

3

60

N/A

6 A

15 AMP

460

3

60

12KW@480V

22 A

30 AMP

230

3

60

N/A

6 A

15 AMP

460

3

60

14KW@480V

25 A

35 AMP

 

 

 

 

 

 

* This model is wired in a wye configuration for the heaters.

Tempstar LT/NB/S Technical Manual 7610-003-61-42 B

Issued: 10-08-2008 Revised: N/A

3

Page 11
Image 11
Jackson Tempstar S Volts Ratings Amps Circuit, Rinse Typical, This model is wired in a wye configuration for the heaters

Tempstar S specifications

The Jackson Tempstar S is a notable name in the realm of industrial heating systems, designed to provide efficient and reliable performance for various applications. Known for its advanced technology and user-friendly features, the Tempstar S stands as a true testament to innovation in heating solutions.

At the core of the Jackson Tempstar S is its powerful heating capacity. This unit can efficiently deliver substantial heat output, making it suitable for large-scale operations. It employs a high-performance burner system that ensures optimal combustion efficiency, translating into reduced fuel consumption and lower operating costs. This energy efficiency is enhanced by advanced control systems that allow for precise temperature regulation.

One of the standout technologies integrated into the Jackson Tempstar S is its advanced control interface. Featuring an intuitive digital display, users can easily monitor and adjust settings. This allows for real-time data feedback, increasing overall usability and operational efficiency. Moreover, the system is designed to offer multiple programmable settings, accommodating a range of operational requirements. This versatility is complemented by robust safety features, including overheat protection and flame monitoring, ensuring that the unit operates safely under various conditions.

Another noteworthy characteristic of the Jackson Tempstar S is its construction. Built with durable materials, the unit is designed to withstand harsh industrial environments. Its compact design allows for easy installation and efficient space utilization, making it a practical choice for facilities with limited space. Additionally, the unit is relatively lightweight, facilitating mobility and ease of repositioning when necessary.

Maintenance is simplified with the Jackson Tempstar S. The design focuses on reducing downtime through easy access to key components, making routine checks and service tasks straightforward. This feature is crucial for industries that rely on continuous operation and cannot afford prolonged interruptions.

Additionally, the Jackson Tempstar S prioritizes eco-friendliness. It adheres to strict emissions standards, contributing to a greener operational footprint without sacrificing performance. This commitment to sustainability reflects the growing emphasis on environmentally conscious manufacturing processes in the industrial sector.

In conclusion, the Jackson Tempstar S offers an impressive combination of efficiency, safety, and ease of use. With its robust features, cutting-edge technology, and durability, it stands as a premier choice for industrial heating applications.