Troubleshooting Chart
PROBLEM |
| PROBABLE CAUSE | REMEDY |
1. Control is on and appears to | A. | Steamer heating up. | A. Allow 2 minutes for steam to |
be functioning, but no steam. |
|
| flow. |
| B. | High limit safety switch tripped. | B. Replace water filter, drain and |
|
|
| flush out steamer and steam |
|
|
| plumbing. Pour six ounces of |
|
|
| water into the steam delivery |
|
|
| tube. Reset high limit safety |
|
|
| switch. |
2.Steam generator will fill and produce steam, but will boil water away without refilling and shut itself off.
A.There is a high concentration of mineral buildup in the tank water because of continued use without draining the tank. This causes faulty water fill opera- tion, and the high temperature safety switch will trip.
A.Replace water filter, drain and flush out steamer and steam plumbing. Pour six ounces of water into the steam delivery tube. Reset high limit safety switch.
3.Excess water is exhausted from the steam head.
A.There is a high concentration of mineral buildup in the tank.
A.Replace water filter, drain and flush out steamer and steam plumbing. Pour six ounces of water into the steam delivery tube.
PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
USE INSTALLATION INSTRUCTIONS SUPPLIED WITH PRODUCT.
Jacuzzi Whirlpool Bath has obtained applicable code (standards) listings generally available on a national basis for products of this type. It is the responsibility of the installer/owner to determine specific local code compliance prior to installation of this product. Jacuzzi Whirlpool Bath makes no representation or warranty regarding, and will not be responsible for any code compliance.