Jacuzzi K339000X manual Electrical Connections, Installation Instructions

Models: K339000X

1 30
Download 30 pages 51.38 Kb
Page 18
Image 18
Electrical Connections

ENGLISH

INSTALLATION INSTRUCTIONS

Electrical Connections

Separate circuits, each must be protected by a Ground Fault Circuit Interrupter (GFCI), are required for the pump/ motor and the RapidHeatTM Heater. Refer to the electrical specification for each model on pages 6-8. Install duplex outlets to the studwall underneath the bathtub, at least 4 inches (10,2 cm) above the floor or in accordance with local building or electrical codes. Duplex outlets are not provided. Because these units are manufactured with an elec- tronic control panel no remote switch or timer is necessary.

Tubs with electronic control panels combine the electrical requirements of the pump/motor and electronic controls into a control box. For these units the power supply cord from the pump/motor runs to the control box. The power supply cord from the control box should be connected to the 20 AMP GFCI circuit.

Before installing electrical connections, inspect the pump/motor and heater nameplates and confirm you have 120 VAC, 20 AMP and 15 AMP service requirements. The GFCI circuits must match these requirements. Care must be taken to connect the 20 AMP pump/motor or control box power cord ONLY to the 20 AMP GFCI circuit and to connect the 15 AMP heater power cord ONLY to the 15 AMP GFCI circuit. Do NOT switch power cords and GFCI circuits.

With a #8 solid copper wire, bond the heater to the house electrical panel or approved local bond. A bonding lug is provided on the heater. With another #8 solid copper wire, bond the pump/motor to the house electrical panel or approved local bond. A bonding lug is provided on the pump/motor.

At initial start-up and before each use thereafter with power ON, push the GFCI test button on each circuit. The reset button should pop out. Push this button in to reset. If the interrupter fails to operate in this manner, there is a ground current flowing or a device malfunction, indicating the possibility of electrical shock. Turn off power and do not use the bath until the source of the problem has been identified and corrected.

DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a Ground Fault Circuit Inter- rupter (GFCI).

CAUTION: Operating the motor/pump without enough water in the bath can cause leaking and permanent damage to the pump. Before power is applied to the installation, make sure the switch is in the OFF position to avoid pump damage.

ELECTRICAL CONNECTION

15 AMP, 3 PRONG PLUG

 

(Heater)

 

20 AMP, 3 PRONG PLUG

 

(Pump/Motor)

DUPLEX

 

 

RECEPT.*

 

4" MIN.

 

OR IN

 

ACCORDANCE

 

WITH LOCAL

 

BUILDING OR

 

ELECTRICAL

 

CODES

 

* INSTALL SEPERATE

 

GFCI PROTECTED CIRCUITS,

HEATER

DUPLEX RECEPTS NOT PROVIDED

18

Jacuzzi Whirlpool Bath K339000X 3/06

Page 18
Image 18
Jacuzzi K339000X manual Electrical Connections, Installation Instructions