ENGLISH
INSTALLATION INSTRUCTIONS
Electrical Connections
Separate circuits, each must be protected by a Ground Fault Circuit Interrupter (GFCI), are required for the pump/ motor and the RapidHeatTM Heater. Refer to the electrical specification for each model on pages
Tubs with electronic control panels combine the electrical requirements of the pump/motor and electronic controls into a control box. For these units the power supply cord from the pump/motor runs to the control box. The power supply cord from the control box should be connected to the 20 AMP GFCI circuit.
Before installing electrical connections, inspect the pump/motor and heater nameplates and confirm you have 120 VAC, 20 AMP and 15 AMP service requirements. The GFCI circuits must match these requirements. Care must be taken to connect the 20 AMP pump/motor or control box power cord ONLY to the 20 AMP GFCI circuit and to connect the 15 AMP heater power cord ONLY to the 15 AMP GFCI circuit. Do NOT switch power cords and GFCI circuits.
With a #8 solid copper wire, bond the heater to the house electrical panel or approved local bond. A bonding lug is provided on the heater. With another #8 solid copper wire, bond the pump/motor to the house electrical panel or approved local bond. A bonding lug is provided on the pump/motor.
At initial
DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a Ground Fault Circuit Inter- rupter (GFCI).
CAUTION: Operating the motor/pump without enough water in the bath can cause leaking and permanent damage to the pump. Before power is applied to the installation, make sure the switch is in the OFF position to avoid pump damage.
ELECTRICAL CONNECTION
15 AMP, 3 PRONG PLUG |
|
(Heater) |
|
20 AMP, 3 PRONG PLUG |
|
(Pump/Motor) | DUPLEX |
| |
| RECEPT.* |
| 4" MIN. |
| OR IN |
| ACCORDANCE |
| WITH LOCAL |
| BUILDING OR |
| ELECTRICAL |
| CODES |
| * INSTALL SEPERATE |
| GFCI PROTECTED CIRCUITS, |
HEATER | DUPLEX RECEPTS NOT PROVIDED |
18
Jacuzzi Whirlpool Bath K339000X 3/06