Controller Mounting
Finished Wall Mounting
The low voltage control can be mounted directly to a finished wall either inside or outside the steam room. Using a 2" hole saw, drill a hole in the finished wall where the control is to be mounted (the control cable should already be
CONTROLLER MOUNTING IN FINISHED WALL
MOUNTING |
| CONTROL |
BRACKET | CONTROL | HOUSING |
|
| |
| HOUSING |
|
CONTROL
COVER
PLATE
SILICON SEALANT
MOUNTING
SCREWS
WALL
CONTROL COVER PLATE
CONTROL HOUSING
Tile Wall Mounting
String the 25' cable from the control location through 1/2" holes in wall studs to the generator. Do not staple through or damage the cable. Use supplied cable only. A one gang junction box (provided) must be installed at the desired location. A mounting plate with a 2" hole is included. Tile up to the 2" hole in the mounting plate. To mount the control apply silicon sealant between the 2 ridges around the perimeter on the back of the control housing and press control against tile. Clean up any excess sealant. Connect the cable from the back of the steam generator to the digital controller.
TILE WALL MOUNTING
STUD
TILE
SINGLE GANG
JUNCTION BOX (PROVIDED)
MOUNTING
PLATE
TILE UP
TO 2" HOLE