Temperature Sensor Mounting
The temperature sensor should be mounted 6" below the ceiling or dome, inside the steam room, but not directly over the steam dispersion head or more than 7 feet above the floor. Using a 7/8" hole saw, drill a hole in the finished wall where the sensor is to be mounted (the sensor cable should already be
WALL SILICONE
SEALANT
Finish Materials
Apply tile (or other finishing material) leaving a 1/8" gap between the finishing material and the base flange lip. Seal this gap with silicone sealant. Leave a minimum 1/4" weep hole at the back and front corners of the base . The weep holes are necessary to allow drainage from leakage through unsealed tiled grout.
Filling the area marked DO NOT FILL will prevent moisture from draining back into the base through the weep holes. This moisture is due to leakage through the tile grout. Sealing the tile grout will prevent this leakage.
| ADHESIVE |
CEMENT | TILE |
BOARD |
|
SILICONE SEALANT
DO NOT
FILL
PIGTAIL
PROBE MUST POINT DOWNWARD
STUD
OPTIONAL
TRIM RING
7/8" HOLE
Flange Mounting
After base is in position secure flange to studs with screws provided. If there is a gap between flange and stud shims MUST be used.
TYPICAL FLANGE MOUNTING DETAIL
FRONT WEEP HOLE
SILICONE
SEALANT
STUD
FLANGE
SHIM IF NECESSARY TO FILL GAPS BETWEEN STUD AND FLANGE
ATTACH WITH SCREWS PROVIDED
1/4" MINIMUM WEEP HOLE
REAR WEEP HOLE
TILE |
1/4" MINIMUM |
WEEP HOLE |
STUD
SILICONE |
SEALANT |