![](/images/new-backgrounds/1099158/9915821x1.webp)
Note: The combined thickness of the tile (or other finish material), adhesive and cement board must not exceed the edge of the vertical wall on the drain side.
This condition will not allow the wall jamb of the steam enclosure to sit flat against the vertical wall.
FINISH SURFACE
DRAIN
TILE FLUSH WITH
VERTICAL WALL
If there is a gap between the finish surface and the vertical wall, a filler piece (included with steam enclo- sure) may be required. Gap must not exceed 3/16". Silicone sealant will also be necessary to eliminate any additional gaps that may be present.
FINISH SURFACE
DRAIN
| TILE NOT FLUSH WITH | |
3/16" | VERTICAL WALL | |
MAXIMUM | VERTICAL WALL | |
GAP | ||
|
Service Access
Service access is through the removable panel. To remove panel, grab the middle of the panel and bow outwards till clips disengage.
SERVICE ACCESS PANEL |
GRAB PANEL IN MIDDLE |
AND BOW OUTWARDS |
To reinstall the panel hold at an angle to the skirt and insert clip under edge of skirt opening. Bow the panel outward and insert clip on other side.
ACCESS
PANEL
BOW ACCESS
PANEL OUTWARD
FROM CENTER
SHELL
Clean-Up After Installation
To avoid dulling and scratching the surface of the shower base, never use abrasive cleaners. A mild liquid detergent and warm water will clean soiled surfaces.
Remove spilled plaster with a wood or plastic edge. Metal tools will scratch the surface. Spots left by plaster or grout can be removed if lightly rubbed with detergent on a damp cloth or sponge.
Paint, tar, or other difficult stains can be removed with paint thinner, turpentine, or isopropyl alcohol (rubbing alcohol).
Minor scratches which do not penetrate the color finish can be removed by lightly sanding with
Major scratches and gouges which penetrate the acrylic surface will require refinishing. Ask your Jacuzzi Whirlpool Bath dealer for special instructions.
9