Fujitsu MCP3064SS, MCM3064SS, MCP3130SS manual Temperature requirements, Installation Requirements

Models: MCM3130SS MCP3130SS MCM3064SS MCP3064SS

1 170
Download 170 pages 22.71 Kb
Page 44
Image 44

Installation Requirements

(b) IC (controller, read Amp)

IC (controller)

IC (read Am p)

Figure 3.1 Surface temperature measurement point (2 of 2)

3.1.2 Temperature requirements

Table 3.1 shows the temperature requirement at the measurement point shown in Figure 3.1.

Table 3.1 Temperature requirements at measurement points

Measurement point

Maximum allowable surface temperature

 

 

Inside the cartridge

55°C (*1)

 

 

IC (controller) surface

85°C

 

 

IC (read Amp.) surface

85°C

 

 

*1 60°C for the optical disk cartridges recommended by Fujitsu (except 1.3 GB).

The following describes a procedure for measuring the temperature inside a cartridge.

1)At the bottom of the cartridge, open a hole large enough for the thermocouple to be inserted as shown in Figure 3.1.

2)Disassemble the cartridge.

3-2

C156-E228-02EN

Page 44
Image 44
Fujitsu MCP3064SS, MCM3064SS, MCP3130SS manual Installation Requirements, Temperature requirements at measurement points