7.7 Bus Conditions
All SCSI devices must deactivate all the bus signals except RST signals and release the bus within 800 ns (Bus Clear Delay) after the RST signal becomes true. After the RESET condition, the SCSI bus must enter the BUS FREE phase. Figure 7.20 shows the RESET condition.
The following are the ODD operations when the RESET condition is detected.
1)All commands including those being executed and those in a stack are cleared.
2)The reserve status of the disk drive is reset.
3)The operation mode set by a message or the command is initialized as when power is turned on.
The current value in the parameter set by a MODE SELECT command is initialized to the saved value last established. If the value is not saved, it is initialized to the default value.
Parameters defined for synchronous transfer between the ODD and SCSI device is cleared. The mode defined for data transfer among all SCSI devices is initialized to asynchronous mode.
4)The UNIT ATTENTION condition is generated for all SCSI devices.
5)The sense data is no longer retained and is cleared.
6)All data read into the data buffer in advance by the
1.The ODD does not generate a RESET condition.
2.The ODD provides only the "hard" RESET condition specified by the SCSI standard.
3.Reset Hold Time is specified to guarantee that any SCSI device
can recognize the occurrence the RESET condition. On the ODD, even if the pulse width is less than 25 ∝ s, the RESET condition is effective.