Specifications

2.1.3 Environmental and power requirements

Table 2.3 lists the environmental and power requirements.

Table 2.3 Environmental and power requirements (1 of 2)

 

Item

 

Specification

 

 

 

 

 

Power

Average

 

+5 VDC±5% (*1), 1.2A (2.7A max)

requirements

 

 

 

Ripple requirement 100mV pp (DC-1 MHz)

 

 

 

 

 

Power

Ready

 

3.9 W (typ) (*2)

 

 

 

 

consumption

Random seek, read or write

6.1 W (typ) (*2)

 

 

 

 

 

(Average)

Power save

 

Pre-idle mode

3.9 W (typ) (*2)

 

mode

 

Idle mode

2.0 W (typ) (*2)

 

 

 

Standby mode

1.2 W (typ) (*2)

 

 

 

Sleep mode

1.2 W (typ) (*2)

 

 

 

 

 

Outer

With panel

 

101.6150.025.4 mm

dimensions

 

 

 

 

 

 

 

 

(W D H)

Without panel

 

101.6148.425.4 mm

 

 

 

 

 

Weight

 

 

 

410 g (with panel)

 

 

 

 

Environmental

Operating

 

Temperature: 5 to 45°C (gradient 15°C /h or less)

requirements

 

 

 

(*3)

 

 

 

 

Relative humidity: 10 to 85% (No condensation)

 

 

 

 

Maximum wet bulb temperature: 29°C or lower

 

 

 

 

 

Idle

 

Temperature: 0 to 50°C

 

 

 

 

Relative humidity: 10 to 85% (No condensation)

 

 

 

 

Maximum wet bulb temperature: 36°C or lower

 

 

 

 

 

Transport

 

Temperature: –40 to 60°C (24 hours or less)

 

 

 

 

Temperature: –20 to 60°C (24 hours or more)

 

 

 

 

Relative humidity: 5 to 90% (No condensation)

 

 

 

 

Maximum wet bulb temperature: 41°C or lower

 

 

 

 

Installation

Tilt angle

 

–5° to +10° (*3)

 

 

 

 

 

2-4

C156-E228-02EN

Page 34
Image 34
Fujitsu MCP3130SS, MCP3064SS, MCM3064SS, MCM3130SS manual Environmental and power requirements 1