7.5 Timing Rule

Table 7.7 Timing specifications (3 of 3)

No.

Name

Standard

Timing specification

 

 

 

 

17

Transfer Period

50 ns

In synchronous data transfer mode, the minimum time

 

 

 

(minimum repetition time) from the leading edge of an

 

 

 

REQ signal to the leading edge of the next REQ signal

 

 

 

or from the leading edge of an ACK signal to the

 

 

 

leading edge of the next ACK signal. The actual value

 

 

 

is defined using a SYNCHRONOUS DATA

 

 

 

TRANSFER REQUEST message exchanged between

 

 

 

the INIT and TARG.

 

 

 

 

Table 7.8 SCSI BUS Timing specifications

No.

Name

Synchronous data transfer mode

Asynchronous

 

 

 

 

 

data transfer

 

 

 

 

 

 

 

Fast-20

Fast-SCSI

SCSI-1

mode

 

 

 

 

 

 

1

Arbitration Delay

2.4s

2.4s

2.4s

2.4s

 

 

 

 

 

 

2

Bus Clear Delay

800ns

800ns

800ns

800ns

 

 

 

 

 

 

3

Bus Free Delay

800ns

800ns

800ns

800ns

 

 

 

 

 

 

4

Bus Settle Delay

400ns

400ns

400ns

400ns

 

 

 

 

 

 

5

Cable Skew Delay

3ns

4ns

4ns

4ns

 

 

 

 

 

 

6

Data Release Delay

400ns

400ns

400ns

400ns

 

 

 

 

 

 

7

Receive Assertion Period

11ns

22ns

70ns

––

 

 

 

 

 

 

8

Receive Hold Time

11.5ns

25ns

25ns

––

 

 

 

 

 

 

9

Receive Negation Period

11ns

22ns

70ns

––

 

 

 

 

 

 

10

Receive Setup Time

6.5ns

15ns

15ns

––

 

 

 

 

 

 

11

Reset Hold Time

25ns

25ns

25ns

25ns

 

 

 

 

 

 

12

Selection Abort Time

200ns

200ns

200ns

200ns

 

 

 

 

 

 

13

Selection Time-out Delay

250ns

250ns

250ns

250ns

 

 

 

 

 

 

14

System Deskew Delay

15ns

20ns

45ns

45ns

 

 

 

 

 

 

15

Transfer Period during

50ns

100ns

200ns

––

 

Synchronous Data Transfer Phases

 

 

 

 

 

 

 

 

 

 

16

Transmit Assertion Period

15ns

30ns

80ns

––

 

 

 

 

 

 

17

Transmit Hold Time

16.5ns

33ns

53ns

––

 

 

 

 

 

 

18

Transmit Negation Period

15ns

30ns

80ns

––

 

 

 

 

 

 

19

Transmit Setup Time

11.5ns

23ns

23ns

––

 

 

 

 

 

 

C156-E228-02EN

7-17

Page 119
Image 119
Fujitsu MCM3130SS, MCP3064SS, MCM3064SS, MCP3130SS manual Timing specifications 3, Scsi BUS Timing specifications