Installation Requirements

3.1.4 Air flow

It is recommended that this optical disk drive be installed in a fanless cabinet. However, if the power supply is included in the same cabinet, the “Temperature Conditions” in 3.1.2 must be met. Furthermore, we recommend that the speed of air drawing in by the device from the left side of the cartridge loading slot in the front panel dose not exceed 0.3m/s for MCM3064SS or MCM3130SS, and dose not exceed 0.1m/s for MCP3064SS or MCP3130SS. If this unit is to be used as a built-in drive, the system fan (if one is supplied) must meet the same conditions.

3.1.5 Air cleanliness

The air cleanliness in the device environment is expressed by the number of dust particles per unit area. Fujitsu recommends using the optical disk drive in the environment of class 5 million or less particle level. (Class 5 million: This means there are 5 million dust particles of 0.5 m diameter or larger per cubic foot. This is equivalent to 0.15 mg/m3.)

3.2 Mounting Requirements

3.2.1 Outer dimensions

Figures 3.2 to 3.3 show the outer dimensions of the optical disk drive and the positions of the mounting holes.

3-4

C156-E228-02EN

Page 46
Image 46
Fujitsu MCP3130SS, MCP3064SS, MCM3064SS, MCM3130SS manual Mounting Requirements, Air flow, Air cleanliness, Outer dimensions