Fujitsu MCM3130SS, MCP3064SS, MCM3064SS manual Error rate, Environmental and power requirements 2

Models: MCM3130SS MCP3130SS MCM3064SS MCP3064SS

1 170
Download 170 pages 22.71 Kb
Page 35
Image 35

2.1 Specifications of Optical Disk Drives

Table 2.3 Environmental and power requirements (2 of 2)

 

Item

 

 

Specification

 

 

 

 

 

 

Vibration/

Operating

 

3.92 m/s2

{0.4 G}

(5 to 500 Hz, Sine Sweep)

shock

 

 

Shock

19.6 m/s2

{2 G}

(10 ms, Half Sine Pulse)

 

 

 

 

 

 

 

 

Idle

 

 

9.8 m/s2

{1.0 G}

(5 to 500 Hz, Sine Sweep)

 

No cartridge, power ON

Shock

49 m/s2

{5 G}

(10 ms, Half Sine Pulse)

 

 

 

 

 

 

 

Transport

Shock

980 m/s2

{100 G}

(10 ms, Half Sine Pulse)

 

 

 

Requirement: Packing specifications specified by Fujitsu

 

 

 

 

Altitude

Operating

3,000 m (10,000 ft) or less

 

 

 

 

 

 

 

Idle

 

12,000 m (40,000 ft) or less

 

 

 

 

 

 

Ambient

Air flow

Not required

 

 

cleanliness

 

 

 

 

 

 

 

 

 

 

Air purity

General office environment or better

 

 

 

(dust particle level: Class 5 million or less particle level)

 

 

 

 

 

*1

During random seek or read/write but excluding pulse waveform at 500 s

 

 

or less

 

 

 

 

*2 Average value at an ambient temperature of 25°C and a voltage of 5 V

*3 The performance is specified at an ambient temperature of 25°C and level placement at 0°.

Note:

1.The current limiter value on the power supply must not exceed 5 A.

2.The specifications for during transport are under the packaging conditions specified by Fujitsu.

3.Note that, concerning the power requirements, a voltage drop may occur depending on the power cable in use.

2.1.4Error rate

Data blocks to be accessed should be evenly distributed on the disk. Errors due to disk defects are not included.

(1) Bit error rate after ECC processing

The error rate after ECC processing must be 10-12or less. An optical disk whose raw error rate is 10-4or less should be used.

(2) Positioning error rate

The positioning error rate must be 10-6or less (with retry).

C156-E228-02EN

2-5

Page 35
Image 35
Fujitsu MCM3130SS, MCP3064SS, MCM3064SS, MCP3130SS manual Error rate, Environmental and power requirements 2