CV-A50 / CV-A60
6. Functions and Operations
Apart from the standard continuous operation, the
6.1. Basic functions
Some of the primary camera functions need a general introduction before the operation modes are described. The list below shows the primary functions from the command list.
SM | Shutter Mode | Normal shutter, Programmable Exposure |
SH | Shutter Speed | Off to 1/10,000 second |
PE | Programmable Exposure | 1.5 H to 1023.5 H |
SC | Scanning Format | Interlaced, |
TR | Trigger Mode | Normal, Edge, PWC, frame delay readout |
|
| Long time exposure, |
FR | Accumulation | Field, Frame |
The shutter SM can be set to normal (SM=0), where the exposure time is selected from 8 fixed step with the command SH, or programmable exposure (SM=1). Here the command PE allows up to 1023 steps with 1 period resolution (64 µs) for edge
The scanning format SC can be selected between interlaced and
The accumulation FR can be field or frame. Fig. 9. show details for frame and field accumulation with shutter OFF, (left(, and shutter on, (right).
The accumulation in all trigger modes is H synchronous. The exposure will start at the first HD pulse after the trigger falling edge. Fig. 8. shows the details. In all triggered shutter modes, the shortest shutter time is limited to ≥1.5 H or 1/10,000. In trigger modes, the exposure time is not limited to the readout time. It can be longer.
HD
Trigger
Accum
X b
Fig. 8. PWC H synchronous accumulation.
Time t0 | t1 | t2 | t3 | t4 |
VD
Frame accum. Xsg1Xsg2
Photo | Field 1 |
charge | Field 2 |
Video out |
|
|
Interlaced | E | O |
|
Field accum. Xsg
Photo | Field 1 |
charge | Field 2 |
Video out
Sync | Interlaced | E | O |
| E | E | |
|
|
Time t0 | t1 | t2 | t3 | t4 |
VD
Frame accum. Xsg1Xsg2
Photo | Field 1 |
charge | Field 2 |
Video out
Interlaced E O
Field accum. Xsg
Photo | Field 1 |
charge | Field 2 |
Video out
Sync | Interlaced | E | O | |
E | E | |||
|
Fig. 9. Frame and field accumulation without shutter (left) and with shutter (right).
- 6 -