CV-L105

6.2.1. Internal Trigger. Scan mode.

In this mode, the camera does not require an EXT TRIG signal to be issued to the camera. The line rate (scan rate) is generated inside the camera. The camera will operate continuously with its internal trigger.

The exposure time is equal to the scanning time set by the SCAN parameter via RS-232C. The permitted range for the scan rate is 151 µs to 32.5 ms (corresponds to 6.6 kHz to 30 Hz). SHUTTER parameter has no function here.

To use this mode:

 

 

Set function:

Trigger

Internal

 

Mode

SCAN

 

SHUTTER value

No function

 

SCAN value

151 µs through 32.5 ms

Input:

Clock, Binning and other functions

 

 

 

Important notes on using this mode:-

It is only recommended to use this mode when there is not change of speed in the object being scanned. If the speed of the object changes, the aspect ratio in the vertical (scanning) direction will change.

Exposure time = SCAN value

Exposure

Data out

LEN

30 MHz 1t=33.3 ns

15 MHz 1t=66.6 ns Value in ( ) is for Binning

Fig. 12. Timing for internal scan mode

- 10 -

Page 11
Image 11
JAI CV-L105 operation manual Internal Trigger. Scan mode