CV-L105
6.2.1. Internal Trigger. Scan mode.
In this mode, the camera does not require an EXT TRIG signal to be issued to the camera. The line rate (scan rate) is generated inside the camera. The camera will operate continuously with its internal trigger.
The exposure time is equal to the scanning time set by the SCAN parameter via
To use this mode: |
|
|
Set function: | Trigger | Internal |
| Mode | SCAN |
| SHUTTER value | No function |
| SCAN value | 151 µs through 32.5 ms |
Input: | Clock, Binning and other functions |
|
|
|
Important notes on using this mode:-
•It is only recommended to use this mode when there is not change of speed in the object being scanned. If the speed of the object changes, the aspect ratio in the vertical (scanning) direction will change.
•
Exposure time = SCAN value
Exposure
Data out
LEN
30 MHz 1t=33.3 ns
15 MHz 1t=66.6 ns Value in ( ) is for Binning
Fig. 12. Timing for internal scan mode
- 10 -