CV-L105

6.2.3. External Trigger. Scan mode.

In this mode, the camera requires an EXT TRIG signal to be issued to the camera. The trigger signal is typical taken from an encoder. The exposure time is equal to the trigger interval. On the EXT TRIG input positive going edge the ongoing integration period is terminated and charge is read out. At the same time it starts a new cycle. The exposure time is therefore dependant of the line rate.

SHUTTER and SCAN parameters has no function here.

The permitted range for the trigger interval is >2120 clk to . Max scan rate is 14285 lines per second.

Trigger width should be >4 clk.

To use this mode:

 

 

Set function:

Trigger

External

 

Mode

SCAN

 

SHUTTER value

No function

 

SCAN value

No function

 

Clock, Binning and other functions

 

Input:

Ext. trigger through the LVDS connector

 

Important notes on using this mode:-

It is only recommended to use this mode when there is not change of speed in the object being scanned. If the speed of the object changes, the exposure time change.

Do not apply a new trigger before the previous result has been read out. >2120 clk.

30 MHz 1t=33.3 ns

15 MHz 1t=66.6 ns Value in ( ) is for Binning

Fig. 14. Timing for external trigger scan mode

- 12 -

Page 13
Image 13
JAI CV-L105 operation manual External Trigger. Scan mode, Timing for external trigger scan mode