Jenn-Air 1300, 1892 manual Do not enter unless you wish to carry out a code load

Models: 1300 1892

1 32
Download 32 pages 27.63 Kb
Page 26
Image 26

4.28Code Loader (AT S2000)

Warning

once activated, a code load must be carried out

 

DO NOT enter unless you wish to carry out a code load

This command enables the firmware contained within the modem to be upgraded using a simple terminal program. The baud rate for the link is fixed at 19,200 baud with no parity.

The command for this is:

AT S2000<CR><LF>

The modem responds with:

Flash Programmer:"karfl3", Ver.:1.00.03, Date:24/10/2001

To update firmware, upload Hermes upgrade *.hex file using

a terminal program that can send 8 bit binary data.

Hermes®, © 2001, Wood & Douglas Ltd.

When this message has been output the code loader software is ready for the new code data to be uploaded. As each line of code is accepted the modem responds with one of 4 responses:

“.”

line written into program memory successfully

“:”

line written into EEPROM memory successfully

“P”

attempt to write into protected memory area, no action taken

“E”

error in writing to memory area

Hermes Operator Note

Page 26 of 32

Page 26
Image 26