Jenn-Air 1892, 1300 manual Connections & Indications, RS232 Connector, Pin No Function

Models: 1300 1892

1 32
Download 32 pages 27.63 Kb
Page 5
Image 5

2CONNECTIONS & INDICATIONS

2.1RS232 Connector

The RS232 connections are made via a 9 way D female with the following connections:

 

 

 

 

 

 

 

Pin No.

Function

 

 

 

 

1

CD Output

 

 

 

 

 

Set (+ve) when a RF signal above a certain level is present at the

 

 

RF connector. The threshold is programmable over 10 levels that

 

 

are defined in section 5.13

 

 

 

 

 

 

 

 

 

 

2

RXD

RS232 data level data output

 

 

 

 

 

 

 

 

 

3

TXD

RS232 level data input

 

 

 

 

 

 

 

 

 

 

4

DTR

RS232 level input

 

 

 

 

 

When set (+ve) by the DTE (host processor) the modem and

 

 

transceiver is turned on. The max/min levels are:

 

 

 

DTR Vin Min.

(off state)

=

-15V

 

 

 

DTR Vin Max.

(off state)

=

+2.5V

 

 

 

DTR Vin Min

(on state)

=

+5V

 

 

 

DTR Vin Max

(on state)

=

+15V

 

 

 

DTR Iin Max(on state) =

4mA

 

 

 

 

 

 

 

 

5

Signal Ground

 

 

 

 

 

 

 

 

 

 

6

DSR

RS232 level output

 

 

 

 

Set (+ve) after power is applied to the modem or when the DTE

 

 

(host processor) sets DTR +ve. The output is active when the

 

 

modem is ready to receive data. The time taken for the output to

 

 

become active is <50ms from when DSR or power is applied to

 

 

the modem.

 

 

 

 

 

 

 

 

 

 

 

7

RTS

RS232 level input

 

 

 

 

 

The RTS input must be set (+ve) for both data and configuration.

 

 

Data is ignored when RTS is clear (-ve).

 

 

 

 

 

 

 

 

 

8

CTS

RS232 level output

 

 

 

 

Set (+ve) if the transmit RS232 data into the modem can be

 

 

accepted and the RTS input is set, it is cleared (-ve) otherwise.

 

 

Clearing of this signal indicates that the input transmit buffer is

 

 

nearly full .The RS232 data must be stopped within 10 bytes of

 

 

this signal being cleared. After this point the data is ignored. The

 

 

CTS signal is set again if there is room for more than 10 bytes.

 

 

 

 

 

 

 

 

9

n/c

 

 

 

 

 

 

 

Table 1 Data Connections

 

 

 

Hermes Operator Note

Page 5 of 32

Page 5
Image 5
Jenn-Air 1892, 1300 manual Connections & Indications, RS232 Connector, Pin No Function