TO CONVERT APPLIANCE FOR USE WITH PROPANEGAS
NATURALGAS
IWARNING
Propane Gas conversion is to be performed by a
ELECTRICALPOWERAND GAS MUST BETURNEDOFF PRIORTO CONVERSION.
WARNINGI
Manifold | 10"W.C. |
IncomingPropane Gas pressure requiredto appliance pressureregulator | 11"- 12"W.C. |
Propane Gas conversion Orifice Hoods are suppliedwith these models. |
|
MODEL CVG4200, CVG4280 SERIES |
|
BLOWER CAN BE
Propane Gas conversion | orifice hoods are supplied with this model. Also available as SERVICE PART NO. 04100251 | ||
Propane Gas input specified | 34,000 BTU/hr. | ||
Left rear burner (LR) | 8,000 BTU/hr. | #66 odfice | .033 inches alia. (Zinc Color) |
Left front burner (LF) | 8,000 BTU/hr. | #66 orifice | .033 inches din. (Zinc Color) |
Right rear burner (RR) | 9,000 BTU/hr. | #63 odfice | |
Right front burner (RF) | 9,000 | #63 odfice |
| TIE DOWN BOLT |
|
| ON EACHI=N | APPLIANCE PRESSURE REGULATOR |
| SLOWERCAN BE SWIVELED 90_ (_1 | WIRING BOX |
MODEL CVG 4100 | SWIVELS21= | COVER |
CONTAINER |
|
Propane Gas conversion orifice hoods are supplied with this model. Also available as SERVICE PART NO. 04100250
.ropane Gas input specified |
| 16,000 BTU/hr, | ||
Left rear burner (LR) | 8,000 | BTU/hr. | #66 odfice | .033 inches dia. (Zinc Color) |
Left front burner (LF) | 8,000 | BTU/hr. | #66 orifice | .033 inches dia. (Zinc Color) |