When installing a 27" wall oven under a 30" cooktop some interference may occur.The followingcutout
notching of the side trims will eliminate the interference of the side trim to the burner box. After cutting, file the side trim edges to eliminate burrs.
_" _-'-_
f
'
_
CAUTION
For European style cabinets (flush front) the required clearance for operation of the oven door is minimum
spacing of 718" between the cutout and the door, hinge or drawer of the cabinet.
Some
1. Cut hole in cabinet to mount oven. Cutout in cabinet should be level and straight,
NOTE: There are no provisions to level the unit after it is installed. An oven that is not level could cause poor baking results,
2. Install plywood floor as shown,
3.Attach unit to the cabinet with four No. 8 x 1" screws supplied with unit inside of envelope containing these instructions.
screws using 1/8" drill. Oven mounting holes are provided in side trim.
4.See instructions at right for
5, See Use and Care Manual for operating instructions,
Installing Bottom Trim Piece
1.,-
Electrical Connections
Unit to be propedycircuitprotectedand wired according to local electrical code and National Electrical Code.
It is advisable that the electrical wiring and hookup be accomplished by a competent e(ectrician.
120/240 VAC or 120/208 VAC 60 Hz. See serial plate on front of unit for power requirements.
The neutral of this unit is grounded to the frame through
the green or solid grounding wire. (The green and the white wires are twisted together at the termination of the
conduit.) If used on new
conductor, untwist or disconnect the green wire and
connect the green wire to ground in accordance with local code. Connect the white neutral to the service neutral.
Connect ail wires to the branch circuit with approved connectors. Use copper or aluminum wire. If aluminum wire is used, use connectors recognized for joining aluminum to copper.
The chart below recommends the minimum circuit
protection and wire size if the appliance is the only unit on
the circuit.
|
|
| RECOMMENDEDI IMUM |
|
ICWRATING. | CIRCUITPROTECTION | WIRESIZE | ||
ONSERIALPLATE | INAMPERS | (AWG) | ||
0 | - | 4.8 | 20 | 12 |
4.9 | ° | 6.9 | 30 | 10 |
7.0- | 9.9 | 40 | 8 | |
10.0- | 1_9 | 50 | 8 | |
12.0 | - | 14.9 | 60 | 6 |
Service
Interruptthe source of electricityto the unitwhen
attempting to repairor servicethe oven. Failureto do this couldresult in a dangerousor even fatal shock.
IMPORTANT - SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE