24.Flame size should be adjusted so it does not extend beyond the edge of the cookware. This instruction is based on safety consideration.
25.This appliance has been tested for safe performance using conventional cookware. Do not use any devices or accessoriesthat are not specifically recommended in this manual. Do not useeyelid covers for the surface burners or stovetop grills. The use of devices or accessories that are not expressly recommended in this manual can create serious safety hazards, result in performance problems and reduce the life of the components of the appliance.
26.Before servicing shut off electrical power supply to appliance.
27 Keep vent area unobstructed when in use.
WARNING
Electrical Grounding Instructions
The appliance is equipped with a three- prong grounding plug for your protec- tion against shock hazard and should
be plugged directly into a properly grounded
IMPORTANT SAFETY NOTICE
AND WARNING
The California Safe Drinking Water and Toxic Enforcement Act of 1986 (Proposition 65) requires the Governor of Cali- fornia to publish a list of substances known to the State of California to causecancer or reproductive harm, and requires businesses to warn customers of potential exposures to such substances.
Users of this appliance are hereby warned that the burning of gas can result in
IMPORTANT NOTICE REGARDING PET BIRDS: Never keep pet birds in the kitchen or in rooms where the fumes from the kitchen could reach. Birds have a very sensitive respiratory system. Fumes released during an oven
SAVE THESE INSTRUCTIONS
Ducting 44444444444444444444444444444444444444444
Ducting Considerations
+6” diameter round or 3 I/J” x IO” rectangularducting should be used for duct lengths
+No more than three 90” elbows should be used. Distance between elbows should be at least IS”.
+Recommended
+There should be a minimum clearance of 6” for cooktop installed near a side wall.
If there is not an obvious improper installation, there may be a concealed problem such as a pinched joint, obstruction in the pipe, etc. Installation is the responsibility of the installer and questions should be addressedfirst by the installer. The installer should very carefully check the ducting installation instructions.