Jenn-Air LI3UNB/W10274316B installation instructions Make Electrical Connection

Models: LI3UNB/W10274316B

1 32
Download 32 pages 54.53 Kb
Page 10
Image 10

4.Align mounting holes and install 5 - 6 x 16 mm screws.

A

B

A.Screw

B.Mounting hole

5.Attach power cord connector to connector on wire box on blower motor mounting plate.

A

B

C

A. Blower motor mounting plate

B. Wire box connector

C. Power cord

Make Electrical Connection

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.Locate junction box inside of the range hood.

A B

A. Terminal box cover

B. Knockout in canopy back into terminal box

E

A

B

C

D F

A. White wires

B. Black wires

C. UL listed wire connectors

D. Green, Bare or Yellow/Green wires

E. Home power supply

F.UL listed or CSA approved ¹⁄₂" strain relief

3.Use UL listed wire connectors and connect black wires (B) together.