XA4200, XA4300

Wiring

Power

GND REM + 12V

®

 

BRIDGE

 

 

 

BRIDGE

 

 

RF

RF

LF

LF +

RR

RR

LR

LR +

FUSE

Power Terminal (+12V)

 

 

Connect directly to the vehicle battery+

 

terminal with 8 gauge wire (minimum).

 

 

 

GND

REM

+ 12V

 

Fuse:

 

 

 

 

 

XA4200

50 AMP

 

 

 

 

XA4300

60 AMP

 

 

 

Spade

 

 

 

 

 

 

 

 

 

 

Connector

 

Fuse or

 

 

 

 

 

Circuit Breaker

 

 

 

 

 

 

 

 

8 Gauge

Battery

Install as close

To Battery+

Wire

 

 

Terminal

 

 

Terminal

to the battery

 

 

 

 

 

 

 

Remote Terminal (REM)

Connect the power antenna/amplifier turn-on lead from the receiver to the AMPLIFIER REMOTE terminal.

GND

REM

+ 12V

Spade

Connector

18 Gauge

Adapter

as possible

To Receiver

Power

Wire

Note:

This amplifier will only work with 12-volt systems.

Antenna Lead

Ground Terminal (GND)

Connect to a good chassis ground. The ground connection should be to clean, unpainted metal to provide a good electrical connection.

GND

REM

+ 12V

Spade

Sheet MetalConnector

Screw

8 Gauge

Wire

Drill 1/8" hole

in chassis

sheet metal

Fuses

Use only blade-type fuses.

Fuse:

 

XA4200

25 AMP

XA4300

30 AMP

FUSE

 

5

5910 XA4CH_E.p65

5

01/23/01, 12:24 PM

Page 5
Image 5
Jensen XA4300, XA4200 warranty Wiring, Power