Electrical Connections

The HVBS-7MW bandsaw is rated at 115/230Vand comes from the factory prewired at 115V. To switch to 230V operation, follow the wiring diagram found on the inside of the motor junction box. The plug end will have to replaced with a plug that is rated at 230V. The coolant pump wiring will have to be changed also. Follow the diagram found on the cooling pump head to switch to 230V operation. This bandsaw is designed for use on a circuit with an outlet that looks like (A) in Figure 5. The bandsaw has a grounding prong as illustrated in (B). A temporary adapter (C) may be used to connect the plug to a two pole receptacle (0) if a properly grounded outlet is not available. The temporary adapter should only be used until a properly grounded outlet can be installed by a qualified electrician. The green colored lug must be securely fastened to the cover plate screw.

Before hooking up to the power source, be sure the power and coolant switches are in the off position.

Hydraulic Feed Selector Operation

The hydraulic feed selector is used to control the blade feed rate and to lock the arm in the vertical

position. To increase the feed rate, turn knob (A, Fig. 6) counter-clockwise. To decrease the feed

rate, turn knob (A, Fig. 6) clockwise. To turn off the flow of hydraulic fluid, turn lever as in figure 6. To turn the hydraulic cylinder on, raise lever (B, Fig. 6) to the 12 o'clockposition.

For a detailed discussion of proper feed rate and cutting speed, refer to the enclosed booklet "Lenox

Guide to Bandsawing" published by American Saw Manufacturing Company. Used by permission.

CURRENT CARRYING PRONGS w

e

,~ I A/ ~

GROUND PRONG

Fig. 5

Fig.6

5

Page 11
Image 11
Jet Tools HBVS-7MW manual Electrical Connections, Hydraulic Feed Selector Operation