Maintenance
To avoid injury while performing maintenance, always unplug the power cord before working on the saw. Failure to comply may cause serious injury!
Never use gasoline or any highly volatile solvents to clean the miter saw. Failure to comply may cause serious injury!
Use only replacement parts that are identical to the parts list at the end of this manual and reassemble exactly as the original assembly to avoid electrical shock. Failure to comply may cause serious injury!
Replacing Carbon Brushes
Replace both carbon brushes when either has less than 1/4 in. length of carbon remaining, or if the spring or wire is damaged or burned.
To inspect or replace brushes:
1.Unplug the saw.
2.Remove the black plastic cap on the side of the motor
Remove the cap cautiously, because it is
3.Pull out the brush and replace.
4.Reverse above steps to reassemble. Tighten the cap snugly, but do not over- tighten.
Replace the brush for the other side in the same manner described above.
Note: To reinstall the same brushes, first make sure the brushes go back in the way they came out. This will avoid a
Lower Blade Guard
Do not use the saw without the lower blade guard. The lower blade guard is attached to the saw for your protection. Should the lower guard become damaged, do not use the saw until the damaged guard has been replaced. Develop a regular check to make sure the lower guard is working properly. Clean the lower guard of any dust or buildup with a damp cloth.
When cleaning the lower guard, unplug the saw from the power source receptacle to avoid unexpected startup.
Do not use solvents on the guard. They could make the plastic “cloudy” and brittle.
Saw Dust
Periodically, saw dust will accumulate under the work table and base. This could cause difficulty in the movement of the worktable when setting up a miter cut. Frequently blow out or vacuum up the saw dust.
If blowing saw dust, wear proper eye protection to keep debris from entering eyes.
Lubrication
All the motor bearings in this tool are lubricated with a sufficient amount of high grade lubricant for the life of the unit under normal operating conditions; therefore, no further lubrication is required.
Lubricate the following as necessary: Chop pivot: Apply light machine oil.
Central pivot of plastic guard: Use light household oil (sewing machine oil) on
29