12
4. If the m it er slot i s not paral l el l oosen the t wo
socket head cap screws (A, Fig. 13) and
adjust for parallel. Tighten the two screws
when the adjustment is complet e.
5. Always maintain a gap of approximately
1/16” between the table edge and disc.
Once the table is square and parallel to the
disc adjust the 90° stop. Loosen hex nut ( B,
Fig. 13) and tighten the set screw (C, Fig.
13) until it contacts the trunnion. Tighten
hex nut.
6. If the point er does not li ne up wit h the “0” on
the scale loosen the screw and adjust f or “0”.
Tight en the screw.
7. The table can be tilted between 0°-45° by
loosening the handle (D, Fig. 13) and tilting
the table to the desired angle. Tighten the
handle. Always maintain a gap of
approx im ately 1/16” between the tabl e edge
and disc.
Note: The belt table can be removed and
the disc table can be used in its place.
There are two holes in the base below the
sanding bel t that will accommodate the disc
table’s support rod and locki ng handle.

Sanding Disc Replacement

1. Disconnect machine from the power
source.
2. Loosen the handle (C, Fig. 14) and remove
the t able assembly (A, Fig. 14) .
3. Turn the knob (B, Fig. 14) and open the
door.
4. Remove old sanding disc by striping from
wheel. M ak e sure t he disc plat e is clean.
5. P ress the new disc firmly into place.

Center P o int

The center point (A, Fig. 15) provided with the
sander can be used for sanding circles. The
center point can be locked in position by
tight ening the set screws (B, F ig. 15).

On/Off Switch

The machine can be turned on by moving the
switch (C, Fig. 15) to the up position. The key
(D, Fig. 15) can be remov ed when the machine
is i n the of f positi on. W i th the key remov ed the
switch will not operate.