Technical specifications

Technical specifications

Width

594 mm

Depth

475 mm

 

 

Height

378 mm

 

 

Capacity of water reservoir

2.5 l

Net weight

28 kg

 

 

Gross weight

31 kg

Supply voltage

230 V

 

 

Rated power

2000 W

 

 

Power absorbed by the heating element

1700 W

Power absorbed by the pump

50 W

 

 

Working pressure

12 bar

Fuse

13 A

 

 

Electrical connection

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.

Electrical connectionWARNING: THIS APPLIANCE MUSTBE EARTHED.

Should the appliance power supply cable need to be replaced, this must be carried out by a Service Force agent. The manufacturer declines any liability should this safety measure not be observed.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the applianceÊs rating plate. The appliance should be fitted with a 13amp plug. The plug should be fitted with a 13amp ASTA approved BS1363/A fuse. The mains lead of the appliance should be connected as described below. The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow – Earth

Blue - Neutral

Brown - Live

In the plug the colours of the wires may not correspond with the markings identified with the terminals in your plug:

1)Connect the Green and Yellow (earth) wire to the terminal in the plug which is marked with the letter "E" or the earth symbol or coloured green and yellow.

2)Connect the Blue (neutral) wire to the terminal in the plug which is marked with the letter "N" or coloured black.

3)Connect the Brown (live) wire to the terminal in the plug which is marked with the letter "L" or coloured red.

4)Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

WARNING: THIS APPLIANCE MUSTBE EARTHED.THE PLUG MUST STILL BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN INSTALLED.

Permanent connectionTHE APPLIANCE SHOULD NOT BE CONNECTED TO THE ELECTRICAL SUPPLY BY MEANS OF AN EXTENSION CABLE

Permanent connection

In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations.

The switch must not break the yellow and green earth cable at any point.

9

Page 11
Image 11
John Lewis JLBICM 01 instruction manual Technical specifications, Electrical connection, Permanent connection