What to do if…
Caution! Before troubleshooting, disconnect the power supply. Only a qualified electrician or competent person must do the troubleshooting that is not in this manual.
Important! There are some sounds during normal use (compressor, refrigerant circulation).
Problem | Possible cause | Solution |
|
|
|
The appliance is noisy. | The appliance is not supported | Check if the appliance stands |
| properly. | stable (all the four feet should be |
|
| on the floor). |
|
|
|
The compressor | The Temperature regulator may | Set a warmer temperature. |
operates continually. | be set incorrectly. |
|
|
|
|
| The door is not closed correctly. | Refer to "Closing the door". |
|
|
|
| The door has been opened too | Do not keep the door open |
| frequently. | longer than necessary. |
|
|
|
| The product temperature is too | Let the product temperature |
| high. | decrease to room temperature |
|
| before storage. |
|
|
|
| The room temperature is too | Decrease the room temperature. |
| high. |
|
|
|
|
Water flows on the rear | During the automatic defrosting | This is correct. |
plate of the | process, frost defrosts on the |
|
refrigerator. | rear plate. |
|
|
|
|
Water flows into the | The water outlet is clogged. | Clean the water outlet. |
refrigerator. |
|
|
|
|
|
| Products prevent that water | Make sure that products do not |
| flows into the water collector. | touch the rear plate. |
|
|
|
Water flows on the | The melting water outlet does | Attach the melting water outlet to |
ground. | not flow in the evaporative tray | the evaporative tray. |
| above the compressor. |
|
|
|
|
There is too much frost | Products are not wrapped | Wrap the products better. |
and ice. | properly. |
|
|
|
|
| The door is not closed correctly. | Refer to "Closing the door". |
|
|
|
| The Temperature regulator may | Set a higher temperature. |
| be set incorrectly. |
|
|
|
|
13